May 17, 2019 ... As to inner conductor sizing... I would use 1AWG Al wires here; spending the extra for copper is a waste, and you can't get away with 2AWG for ...

www.reddit.com/r/askanelectrician/comments/gdne2a/attempting_to_run_a_sub_panel_to_a_shop_wire_help

May 5, 2020 ... I was planning on using conduit from where the wire leaves the house ... sub panel with a grounding rod at the sub panel. the aluminum wire ...

www.thespruce.com/sub-panels-for-additional-space-1152719

May 29, 2021 ... Sub-panels are smaller in amperage size than the main electrical service panel. This is what they are and what they are used for in-home wiring.

askinglot.com/what-wire-do-i-need-for-a-100-amp-subpanel

Apr 25, 2020 ... Use 3 AWG copper or 1 AWG aluminium for the current carrying conductors. Does sub panel wire need to be in conduit? Re: Subpanel wire run ...

www.homedepot.com/p/questions/Southwire-13102999-2-2-2-4-Aluminum-SER-Wire-By-the-Foot/205001908/2

used for 100 amp subpanel attached garage..running 60 ft...only question is do ... of conduit should I use in a metal building also copper or aluminum wire ...

upgradedhome.com/wire-size-for-100-amp-sub-panel-200-feet-away

If you are running into the issue of what size wire to use, it is a fairly common problem. Generally speaking, you will need 1 AWG copper or 2/0 aluminum ...

www.youtube.com/watch?v=W9Mrw_olGPQ

Subpanels only get SER Cable! 18,194 views18K views. Jan 9, 2020 ... Why Neutrals and Grounds are Separated in a Sub Panel ... Aluminum v.

www.wurtsboroelectric.com/safewire.html

There are many types of aluminum wiring still in use today. ... breaker panel) and feeder conductors (i.e. from your main breaker panel to a sub panel).

findanyanswer.com/can-you-use-aluminum-wire-service-entrance

May 9, 2020 ... Aluminum can be used for main service entrance and sub panels. As Firestarter said, fine for sub panels. Aluminum Cons: Larger conductors ...

www.greentractortalk.com/threads/direct-burial-cable-for-sub-panel.195971

Feb 9, 2020 ... I need bury 115 ft to run a 100 amp sub panel to my pole barn from my house. I plan on using aluminum 2-2-2-4 direct burial mobile home ...

sawmillcreek.org/showthread.php?151998-aluminum-vs-copper-fo-sub-pannel

Nov 10, 2010 ... I would not use aluminum for any wiring. ... I assume you're talking about the main feed line to your sub panel. Price out the two types of ...