2 (310.2) Gas pipe bonding – CSST. A gas piping system that contains any CSST shall be electrically continuous and shall be directly bonded to the electrical ...

www.xcelenergy.com/staticfiles/xe-responsive/Start,%20Stop,%20Transfer/CSST-Direct-Bonding-Tech-Bulletin.pdf

Direct bonding is required for gas piping systems incorporating standard (yellow) ... The bonding conductor shall be no smaller than a 6 AWG copper wire or ...

homeflex.com/downloads/HOME-FLEX_Bonding_Instructions.pdf

The bonding clamp attachment point may be at any location within the gas piping system. However, the shortest practical bonding wire length will improve the ...

www.lincenergysystems.com/blog/best-tracer-wire-locating-underground-gas-lines

Jan 21, 2016 ... If the line needs repair or maintenance, an underground wire tracer or above-ground wire detector can locate the non-energized pipe. Request a ...

popularask.net/does-gas-pipe-need-to-be-bonded

ANSWER: Yes, I said metal gas piping should be bonded to the supply system grounded conductor. ... Beside this, How much does it cost to bond a gas line?

www.dslreports.com/forum/r27564623-Bonding-propane-piping-question

The pipe to the stove is about 3 feet away from the ground wire and ... CSST gas piping systems shall be bonded to the electrical service ...

www.urbandale.org/DocumentCenter/View/104/Corrugated-Stainless-Steel-Tubing-CSSTBonding-PDF?bidId=

Sep 1, 2010 ... CSST gas piping systems must be bonded to the electrical service grounding ... Use a 6 AWG copper bonding wire from the clamp to the:.

forums.redflagdeals.com/bonding-gas-line-electrical-ground-questions-house-has-csst-pex-1075170

I have a ground wire coming out of the panel where they connect which grounds to a nearby copper water pipe. Then my gas grounded to the copper ...

discover.hubpages.com/living/The-Importance-of-Grounding-Your-Gas-Line

Sep 14, 2012 ... My gas line was not grounded: Yellow gas line and no copper wire ... Gas lines are bonded and only require extra bonding if its CSST and ...

portal.ct.gov/-/media/DAS/Office-of-State-Fire-Marshal/csstbondclarification.pdf

Jun 5, 2015 ... The bonding jumper shall not be smaller than 6 AWG copper wire or equivalent. Gas piping systems that contain one or more segments of CSST shall ...

www.hvactechgroup.com/hvacforum/index.php?topic=318.0

Sep 22, 2007 ... The OESC requires that the gas piping be bonded to the electrical system bonding conductor by a #6 AWG copper wire. The code also requires ...