barneyselectric.com/csst.htm

Grounding a gas line is as simple as attaching a wire from the gas pipe to the service panel or ground rod. Why Bond Your Gas Lines? Bonding is required to ...

www.tssa.org/Modules/News/index.aspx?feedid=a432fea8-34f2-4fb2-97ec-b393c44fc0eb,4c142457-0d0f-4773-a511-7866672bbffa,ff34d029-6100-428b-87a6-89ed3918dcd4,7b882e28-3b4f-4044-ba7f-6df58a31ce1b,5b7aff3b-3f29-440e-b6f7-f3341638e717,3b0a683e-3289-4504-a528-320a2d741fa6,b32b6789-a2cf-4413-a8b2-cc829952ee7e,4ca86901-c2ab-453b-b95b-123f516c0c9f,f53a4329-8b60-4d38-acc2-ffff6c74d7f1,e018aaf8-86ba-4954-902c-489db3ded3c8&newsId=156d43a8-1ba9-43e1-9d16-40e5ccbd8148

Mar 6, 2019 ... Rule 10-406 requires the interior gas piping system to be bonded with a minimum of a N0. 6 AWG copper or a No. 4 AWG aluminum conductor, ...

www.adamselectric.coop/wp-content/uploads/2015/02/Grounding-Bonding.pdf

It is important to note that metal underground gas piping systems are not ... various types of Main Bonding Jumpers — including a wire, bus, screw, ...

www.homedepot.com/c/ab/grounding-vs-bonding/9ba683603be9fa5395fab901967776a8

Bonding. Metal Frame Bonded With Grounding Wire. Electrical bonding is connecting multiple ... Metal gas piping; Metal water piping; Metal sprinkler piping ...

lightning.org/wp-content/uploads/2012/10/Tech_Letter-NFPA_54_to_Include_Bonding_8-08.pdf

to bonding and grounding of gas pip- ... “Bonding of Gas Lines,” dated. February, 2005. This Tech Letter ... AWG copper wire. 7.13.2 Gas piping shall not be ...

www.hvactechgroup.com/hvacforum/index.php?topic=1540.0

Oct 6, 2014 ... The gas piping system shall be considered to be direct-bonded when installed ... o The shortest practical bond wire length will improve the ...

www.city-data.com/forum/house/753443-bonding-gas-line.html

It means attach a ground wire to it. It would be the same as when the electrical panel is grounded (bonded) to the water lines- if the water ...

www.bergquistinc.com/sites/default/files/academy_spec_sheets/Gastite%20Bonding%20Instructions.pdf

Jun 3, 2010 ... CSST is required for all gas-piping systems incorporating Gastite ... The bonding conductor shall be no smaller than a 6 AWG copper wire or ...

www.urbandale.org/DocumentCenter/View/104/Corrugated-Stainless-Steel-Tubing-CSSTBonding-PDF?bidId=

Sep 1, 2010 ... CSST gas piping systems must be bonded to the electrical service grounding ... Use a 6 AWG copper bonding wire from the clamp to the:.

www.nh.gov/safety/divisions/firesafety/bulletins/documents/IB-CSST-2012-04.pdf

Jul 22, 2012 ... the bonding of CSST gas piping system to the electrical grounding system of your home. This bonding jumper or wire is connected to the CSST ...

homesmsp.com/2012/08/do-you-have-csst-gas-piping-check-for-bonding.html

What does proper bonding look like? All manufacturers of CSST require the systems to be bonded in a specific manner – there needs to be a separate ground wire ...