Web Results
arcelectric.com/residential-home-services/gas-line-bonding

All CSST manufacturers now recommend the direct bonding of CSST to the house electrical system ground using 6 AWG copper wire or equivalent.

www.ci.faribault.mn.us/DocumentCenter/View/181/Wardflex-Bonding-Grounding-PDF

A: Yes, according to NFPA 54 section 7.13, the gas-piping system “…shall be consid- ... Q: Should WARDFLEX be directly bonded using a bonding clamp and wire ...

www.electriciantalk.com/threads/bonding-gas-pipe.262272

Jun 5, 2018 ... Inspector passed my panel change today but said he would like to see a ground wire from the water main to gas piping instead of a jumper ...

www.technicalsafetybc.ca/alerts/information-bulletin-electrical-bonding-requirements-gas-piping-or-tubing-systems

Aug 14, 2017 ... The purpose of bonding interior metal piping to the building grounding system is to provide a safe electrical path to ground should the metal ...

www.cranfordnj.org/building-department/files/csst-bonding-information

The bonding jumper shall be not smaller than 6 AWG copper wire or equivalent. ❖ This section addresses gas pipe bonding specific to CSST and does so for ...

www.lcar.com/csst-gas-pipe-boding

Jul 26, 2019 ... Grounding provides safety in case of a fault in a structure's branch circuit wiring that feeds lighting, receptacles and appliances. A fault is ...

www.prattplumbing.net/should-you-have-bonding-wire-on-your-water-heater

Oct 10, 2019 ... It typically has two brass clamps with a thick copper wire strung between them. One clamp is placed on the cold water pipe while the other goes ...

www.startribune.com/bonding-gas-piping/449206123

Oct 3, 2017 ... To make it really simple, when metal that can carry electricity (but shouldn't) gets connected together to eliminate potential, we call it ...

www.rockwallelectric.com/grounding-and-bonding

Corrugated Stainless Steel Tubing (CSST) is a flexible, stainless steel pipe used to supply natural gas and propane in residential, commercial and ...

portal.ct.gov/-/media/DAS/OEDM/Design-and-Trades/new_installation_requirements_for_csst_gas_piping_system-dtc_2016.pdf?la=en

The bonding jumper shall not be smaller than 6 AWG copper wire or equivalent. Gas piping systems that contain one or more segments of CSST shall be bonded ...

homeflex.com/downloads/HOME-FLEX_Bonding_Instructions.pdf

The bonding clamp attachment point may be at any location within the gas piping system. However, the shortest practical bonding wire length will improve the ...