www.garagejournal.com/forum/threads/what-size-aluminum-wire-for-100amp-sub-panel.260903

Sep 4, 2014 ... pattenp said: Use 2/0 Al if you want a full 100A service with less than 3% voltage drop. You will need to buy lugs to fit the wire to the bars.

aic-controls.com/wire-size

AWG, (mm²), Copper, Aluminum, Copper, Aluminum. The tables below are intended to be a general guide for wire size and amp ratings.

findanyanswer.com/what-size-wire-do-i-need-to-run-a-100-amp-sub-panel

Mar 26, 2021 ... What size aluminum wire do I need for 100 amp service? Use 3 AWG copper or 1 AWG aluminium for the current carrying conductors.

www.wireandcableyourway.com/blog/wire-cable-to-run-100-amp-outdoor-service-to-shed

Dec 27, 2017 ... We also offer single conductor XHHW-2 Aluminum Building Wire. Our most popular aluminum wire for 100 amps service would be our #2 AWG XHHW-2 ...

www.wireandcableyourway.com/blog/what-size-service-wire-100-amp-sub-panel

Mar 21, 2014 ... Multi-Conductor #2 gauge Aluminum Wire · Rated for direct burial - no need for conduit.

www.hunker.com/13414178/what-size-conduit-and-wire-do-you-use-on-a-100-amp-service

When it comes to the lines connecting master and secondary panels, where the line will carry as much as a full 100 amps, use a 2-gauge non-metallic sheathed ...

askinglot.com/what-wire-do-i-need-for-a-100-amp-subpanel

Apr 25, 2020 ... Use 3 AWG copper or 1 AWG aluminium for the current carrying conductors. Does sub panel wire need to be in conduit? Re: Subpanel wire run ...

www.houzz.com/discussions/2637941/ser-2-2-2-4-for-100-amp-sub-panel-copper-or-aluminum

I know very often aluminum ser is used for feeders to sub panels but know aluminum wiring requires special wiring methods. When aluminum is used from a 100 ...

www.doityourself.com/forum/electrical-ac-dc/221763-100a-garage-service-panel-can-i-use-aluminum-wire.html

You cannot run individual wires whether copper or aluminum thru your walls. Individual wires must be in conduit. There is nothing wrong with using aluminum ...

forum.nachi.org/t/incorrect-wire-size-for-a-100-amp-circuit-breaker/161758

... to be a #8 copper wire (red, black and white) installed on a 100 amp ... Also copper SEC are always favored over aluminum correct???

diy.stackexchange.com/questions/29057/what-wire-gauge-do-i-need-for-a-100-amp-subpanel-at-the-end-of-a-60-wire-run

Mar 14, 2016 ... You need a 3-3-3-5 copper SER cable to carry 100 amps (that's three #3 gauge for the two hot wires and the neutral and a #5 gauge for the ground). enter image&...