The effectiveness of insulation is commonly evaluated by its R-value. However, an R-value does not take into account the quality of construction or local environmental factors for each building. Construction quality issues include inadequate vapour barriers, and problems with draft-proofing. In addition, the construction properties and density of the insulation material itself is critical. For example, according to Leah Twings, Quality Compliance Manager of Textrafine Insulation, fiberglass insulation materials made from short strands of glass layered over each other is not as durable as insulation made from long entangled strands of glass.
How much insulation a house should have depends on building design, climate, energy costs, budget, and personal preference. Regional climates make for different requirements. Building codes specify only the bare minimum; insulating beyond what code requires is often recommended.
The insulation strategy of a building needs to be based on a careful consideration of the mode of energy transfer and the direction and intensity in which it moves. This may alter throughout the day and from season to season. It is important to choose an appropriate design, the correct combination of materials and building techniques to suit the particular situation.
In cold conditions, the main aim is to reduce heat flow out of the building. The components of the building envelope - windows, roofs and walls, and air infiltration are all important sources of heat loss; in an otherwise well insulated home, windows will then become an important source of heat transfer.. The resistance to conducted heat loss for standard glazing corresponds to an R-value of about 0.17W/m2/Ko (compared to 2-4W/m2/Ko for glasswool batts). Losses can be reduced by good weatherisation, bulk insulation, and minimising the amount of non-insulative (particularly non-solar facing) glazing. Indoor thermal radiation can also be retarded with spectrally selective (low-e, low-emissivity) glazing. Some insulated glazing systems can double to triple R values.
In hot conditions, the greatest source of heat energy is solar radiation.This can enter buildings directly through windows or it can heat the building shell to a higher temperature than the ambient, increasing the heat transfer through the building envelope.The Solar Heat Gain Co-efficient (SGHC) (a measure of solar heat transmittance) of standard single glazing can be around 78-85%.. Solar gain can be reduced by adequate shading from the sun, light coloured roofing, spectrally selective (heat-reflective) paints and coatings and various types of insulation for the rest of the envelope. Specially coated glazing can reduce SHGC to around 10%. Radiant barriers are highly effective for attic spaces in hot climates . In this application, they are much more effective in hot climates than cold climates. For downward heat flow, convection is weak and radiation dominates heat transfer across an air space. Radiant barriers must face an adequate air-gap to be effective.
If refrigerative air-conditioning is employed in a hot, humid climate, then it is particularly important to seal the building envelope. Dehumidification of humid air infiltration can waste significant energy. On the other hand, some building designs are based on effective cross-ventilation instead of refrigerative air-conditioning to provide convective cooling from prevailing breezes.
Optimal placement of building elements (e.g. windows, doors, heaters) can play a significant role in insulation by considering the impact of solar radiation on the building and the prevailing breezes. (See Passive Solar Design) Reflective laminates can help reduce passive solar heat in pole barns, garages and metal buildings.
See insulated glass for discussion of windows.
The thermal envelope defines the conditioned or living space in a house. The attic or basement may or may not be included in this area. Reducing airflow from inside to outside can help to reduce convective heat transfer significantly .
Ensuring low convective heat transfer also requires attention to building construction (weatherization) and the correct installation of insulative materials .
The less natural airflow into a building, the more mechanical ventilation will be required to support human comfort. High humidity can be a significant issue associated with lack of airflow, causing condensation, rotting construction materials, and encouraging microbial growth such as mould and bacteria. Moisture can also drastically reduce the effectiveness of insulation by creating a thermal bridge(see below). Air exchange systems can be actively or passively incorporated to address these problems.
A building design may have limited capacity for insulation in some areas of the structure. A common construction design is based on stud walls, in which thermal bridges are common in wood or steel studs and joists, which are typically fastened with metal. Notable areas that most commonly lack sufficient insulation are the corners of buildings, and areas where insulation has been removed or displaced to make room for system infrastructure, such as electrical boxes (outlets and light switches), plumbing, fire alarm equipment, etc.
Thermal bridges can also be created by uncoordinated construction, for example by closing off parts of external walls before they are fully insulated. The existence of inaccessible voids within the wall cavity which are devoid of insulation can be a source of thermal bridging.
Some forms of insulation transfer heat more readily when wet, and can therefore also form a thermal bridge in this state.
The heat conduction can minimized by any of the following: reducing the cross sectional area of the bridges, increasing the bridge length, or decreasing the number of thermal bridges.
There are essentially two types of building insulation - Bulk Insulation and Reflective Insulation. Most buildings use a combination of both types to make up a total building insulation system. The type of insulation used is matched to create maximum resistance to each of the three forms of building heat transfer - Conduction, Convection, and Radiation.
Bulk insulators block conductive heat transfer and convective flow either into or out of a building. The denser a material is, the better it will conduct heat. Because air has such low density, air is a very poor conductor and therefore makes a good insulator. Insulation to resist conductive heat transfer uses air spaces between fibers, inside foam or plastic bubbles and in building cavities like the attic. This is beneficial in an actively cooled or heated building, but can be a liability in a passively cooled building; adequate provisions for cooling by ventilation or radiation are needed.
Some radiant barriers are spectrally selective and will preferentially reduce the flow of infra-red radiation in comparison to other wavelengths. For instance low-emissivity (low-e) windows will transmit light and short-wave infra-red energy into a building but reflect back the long-wave infra-red radiation generated by interior furnishings. Similarly, special heat-reflective paints are able to reflect more heat than visible light, or vice-versa.
Thermal emissivity values probably best reflect the effectiveness of radiant barriers. Some manufacturers quote an 'equivalent' R-value for these products but these figures can be difficult to interpret.
A film of dirt or moisture can alter the emissvity and hence the performance of radiant barriers.
Insulating buildings during construction is much easier than retrofitting, as generally the insulation is hidden, and parts of the building need to be deconstructed to reach them.
This kind of service can often be facilitated by:
Utility companies are usually eager to provide this service, as well as loans and other incentives to insulate. They also often provide incentives to switch, for example, if you are an oil customer considering switching to natural gas. It is possible to obtain simple energy audits (without the blower tests) from some utilities and US state agencies for free. An example is the Energy Trust of Oregon program, which provides simplified energy audits and compact fluorescents to homeowners at no cost.
Where to look for insulation recommendations:
Materials
Design
Construction
Other